High performances simulation of ultrasonic fields for Non Destructive Testing
1 CEA LIST, CEA Saclay Digiteo Labs, pc 120, 91191 Gif-sur-Yvette cédex, France
2 LRI (Laboratoire de Recherche en Informatique), UMR8623, Universite Paris-Sud 11, France
* Corresponding Author, E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
Abstract
Ultrasonic imaging is a commonly used method to detect and identify defects in a mechanical part in nuclear applications. Nowadays massively parallel architectures enable the simulation of ultrasonic field emitted by a phased array transducer inspecting a part across a coupling medium. In this paper, regular field computation model will be discussed along its implementations on General Purpose Processors (GPP) and Graphic Processing Units (GPU).
Key words: non-destructive testing / ultrasonic simulation / general purpose processors / graphic processing units / massive parallelism